1. High Efficiency and Energy Saving

MotorSeries Rated Power(kW) Poles Nominal Voltage Our Standards Industrial Standards Energy Saving Projects
YB2 355 2 6000 95.95 94.9 94.6
YB2 450 2 10000 95.67 95.2 95.1
YB2 500 2 10000 96.05 95.3 95.2
YB2 800 2 10000 96.89 95.7 95.5
YB2 900 2 10000 96.44 95.8 95.6
YB2 450 4 6000 95.3 95.2 95.1
YB2 500 4 6000 95.31 95.3 95.1
YB2 630 4 6000 95.8 95.5 95.5
YB2 800 4 10000 96.09 95.7 95.7
YB2 900 4 6000 96.81 95.8 95.9
YB2 1000 4 10000 96.54 95.9 95.9
YB2 1800 4 6000 96.86 96.4
YB2 400 6 10000 95.05 94.6 94.4
YB2 400 10 10000 95.48 94.5 94.3
Y 630 2 10000 95.92 94.6 95.6
Y 710 2 10000 96.14 94.7 95.7
Y 1250 2 10000 96.87 95.4 96.3
Y 2500 2 10000 97.02 96 96.8
Y 630 4 10000 95.51 94.4 95.5
YKK 900 8 10000 95.94 94.8 95.8


High efficiency and energy saving of economic value and social value

YFKS900-4P、10000kW、10kV Motor

If the efficiency could increase from 96.0% to 97.0%, around 859 thousands kWh of electricity could be save for every year, and it is 21.48 million kWh for 25 years. More than100 hope primary schools could be build just based on these saves.

To participate in drafting national standard GB30254-2013《Limited values of energy efficiency and energy efficiency grades of high-voltage three-phase squirrel cage asynchronous motors》, Released on December 18, 2013,  and implemented in September 1, 2014.

Every percent increase of energy efficiency in the national industrial motor could annually save electricity for 26 billion kwh, which equivalent to the output of a 3.25 million kilowatts capacity of power plants.


 2.Low Vibration

Motor Series

Rated Power kW

Poles

Nominal Voltage
V

Virtual value of vibration velocity mm/s

Our Results

Average

Max Value

National Standards

YB2

355

2

6000

0.8

0.7

1.3

0.3

0.5

1.1

0.8 

1.3 

2.3 

YB2

450

2

10000

1.2

1

0.8

1.4

1.3

1.8

1.3 

1.8 

2.3 

YB2

500

2

10000

0.7

0.4

1.5

0.8

0.9

1.6

1.0 

1.6 

2.3 

YB2

800

2

10000

1.6

1.2

1.1

1.8

1.1

1.2

1.3 

1.8 

2.3 

YB2

900

2

10000

1.3

0.9

1.2

0.9

1.1

1.6

1.2 

1.6 

2.3 

YB2

450

4

6000

0.7

0.6

0.6

0.5

0.3

0.5

0.5 

0.7 

2.3 

YB2

500

4

6000

0.7

0.8

0.9

0.4

0.7

0.6

0.7 

0.9 

2.3 

YB2

630

4

6000

0.3

0.5

0.4

0.3

0.3

0.5

0.4 

0.5 

2.3 

YB2

800

4

10000

0.3

0.4

0.4

0.3

0.3

0.3

0.3 

0.4 

2.3 

YB2

900

4

6000

0.8

0.7

0.4

0.6

0.6

0.4

0.6 

0.8 

2.3 

YB2

1000

4

10000

0.4

0.5

0.7

0.5

0.6

0.7

0.6 

0.7 

2.3 

YB2

1800

4

6000

1

1.1

0.8

0.5

0.7

0.7

0.8 

1.1 

2.3 

YB2

400

6

10000

0.1

0.2

0.3

0.1

0.2

0.3

0.2 

0.3 

2.3 

YB2

400

10

10000

0.2

0.3

0.2

0.3

0.3

0.3

0.3 

0.3 

2.3 

Y

630

2

10000

0.4

0.4

0.4

0.7

0.3

0.3

0.4 

0.7 

2.3 

Y

710

2

10000

1.6

1

1.1

1.2

1.3

1.5

1.3 

1.6 

2.3 

Y

1250

2

10000

1.1

0.8

0.9

1.3

1.6

1.6

1.2 

1.6 

2.3 

Y

2500

2

10000

1

1.1

1.6

1.4

1.9

1.9

1.5 

1.9 

2.3 

Y

630

4

10000

0.6

0.6

0.5

0.7

0.3

0.4

0.5 

0.7 

2.3 

YKK

900

8

10000

0.2

0.2

0.3

0.3

0.2

0.1

0.2 

0.3 

2.3 

3.Low Noise

Motor Series

Rated Power kW

Poles

Nominal Voltage
V

NoisedBA))

Our Standards Lp

Our Standards Lw

National Standards Lw

YB2

355

2

6000

83.9 

98.7 

111

YB2

450

2

10000

83.6 

98.4 

111

YB2

500

2

10000

83.8 

98.6 

111

YB2

800

2

10000

84.3 

98.8 

112

YB2

900

2

10000

83.2 

98.3 

112

YB2

450

4

6000

82.3 

86.3 

108

YB2

500

4

6000

82.5 

97.3 

108

YB2

630

4

6000

83.0 

97.8 

111

YB2

800

4

10000

84.6 

99.7 

111

YB2

900

4

6000

84.3 

99.4 

111

YB2

1000

4

10000

84.0 

99.5 

111

YB2

1800

4

6000

84.4 

100.4 

113

YB2

400

6

10000

80.4 

95.2 

105

YB2

400

10

10000

77.6 

92.7 

101

Y

630

2

10000

77.4 

92.5 

109

Y

710

2

10000

84.1 

98.9 

109

Y

1250

2

10000

84.7 

100.2 

110

Y

2500

2

10000

84.6 

100.7 

110

Y

630

4

10000

73.7 

88.7 

109

YKK

900

8

10000

75.8 

92.3 

105